Home › Industrial Spray Booths
The spray booth captures overspray, protects the finish from dust and keeps the operator's air clean. Lynvex booths for production painting include water curtain booths, sized to your largest part and integrated with your line or used stand-alone.

In a water curtain booth, a continuous sheet of water flows down the back panel and traps paint overspray, which suits liquid paint lines and frequent colour changes. Dry-filter booths trap overspray in filter media instead and suit powder or low-volume work. Booth size follows the largest part plus working clearance, and extraction is sized to the booth face area and your paint system.
| Booth type | Overspray capture | Suits |
|---|---|---|
| Water curtain booth | Flowing water wall washes overspray down | Liquid paint, colour changes, line production |
| Dry-filter booth | Disposable filter media | Low-volume and touch-up work |
| Mini water curtain booth | Water curtain, compact body | Small parts and lab-scale spraying |
Send the largest part's dimensions, whether spraying is manual or automatic, and whether the booth stands alone or sits in a conveyor line. If you spray flammable coatings, say which ones: booth electrics and extraction are specified accordingly.
Spray booths serve any production painting that values finish quality and operator air: liquid paint lines, stand-alone spray stations, touch-up and repair bays. A booth's real product is controlled air — overspray carried away predictably, dust kept off wet film, and a workspace where a painter or a machine can repeat the same result all shift.
Booth choice also follows the coating's safety profile. Solvent-based paints need extraction and electrics specified for flammable vapours; water-based paints relax some requirements but punish poor airflow with slow drying and dust nibs. State your paint system in the inquiry so the booth is specified for it, not for a generic case.
A booth performs as maintained: water curtain booths need sludge removal and water level checks; dry booths need filter changes before the filters load up and starve the airflow. In both types the symptom of neglect is the same — finish defects that look like coating problems but are airflow problems. The proposal includes the maintenance rhythm for your paint type and volume.
Yes. Booths are built to your conveyor opening and line height. Send the cross-section and we will match it.
The booth tank circulates the curtain water; paint sludge is skimmed or filtered. Your site's discharge rules decide the treatment step, which we will flag in the proposal.